Fire Protection for Aged Care Providers and Retirement Living

For aged care providers, retirement living operators and community housing providers across South East Queensland. Safe QLD Fire Protection maintains sprinklers, fire pumps, hydrants, detection, EWIS and VESDA to AS 1851-2012, with emergency lighting to AS/NZS 2293.2, fire doors and portables on the same attendance, planned around residents and care routines.

Cm3 Prequalified Staged Works on Occupied Buildings Critical Defects Notified Within 4 Hours 24/7 On Call, 2 Hour Response
Aged Care

When Residents Can't Self-Evacuate, Every System Must Work First Time

In an aged care home, evacuation is not a fire drill sprint to the carpark. Many residents have limited mobility, use walkers or wheelchairs, or live with dementia, so evacuation is staged, staff-assisted and built around fire compartments. That places enormous weight on working sprinklers, early detection, intact fire doors and emergency lighting that actually comes on. Our job is to make sure every one of those layers performs when it matters most.

AS 1851-2012 AS 2118 AS 2419.1 AS 1670.1 AS/NZS 2293.2 NCC QFD
Numbered sprinkler risers, alarm valves and pressure gauges in a high-rise sprinkler valve room maintained by Safe QLD Fire Protection

Complete Coverage for Vulnerable Occupancy Buildings

One contractor holds every system on the site, so the board and the accreditation team see one schedule and one set of records.

  • Sprinkler systems, monthly to five-yearly (AS 1851-2012 Section 2, AS 2118)
  • Sprinkler zone isolation testing coordinated with care staff
  • Fire pumpsets and water storage tanks (AS 1851-2012 Sections 3 and 5)
  • Fire hydrants and boosters (AS 1851-2012 Section 4, AS 2419.1)
  • Fire detection, alarm, EWIS and VESDA testing (AS 1851-2012 Section 6, AS 1670.1)
  • On the same attendance: emergency and exit lighting (AS/NZS 2293.2), fire door and passive fire inspections to protect compartmentation, extinguishers and hose reels
  • Digital service report and signed LB6A entry after every visit, for accreditation and audit
Care-First Servicing

Testing Done Around Residents, Not Over Them

Technician holding a sound level meter reading 84.7 dBA while testing alarm audibility

Quiet, Coordinated and Fully Planned

Unexpected alarm tones can genuinely distress aged care residents. Our technicians plan every visit with your facility manager: alarm tests are coordinated and announced, work is staged wing by wing, and isolations are kept as short as possible, with systems reinstated and verified the same shift. On upgrades and new works we stage commissioning area by area so residents stay protected throughout.

  • Servicing scheduled around meals, rest periods and care routines
  • Alarm testing coordinated with staff so residents are never startled
  • Sprinkler and detection isolations staged, minimised and signed back in
  • Site-inducted technicians working to your visitor, infection control and resident-safety procedures
  • 24/7 on call for urgent defects, with a 2 hour emergency response from the Gold Coast to the Sunshine Coast
Multi-site provider? We run AS 1851 programs across whole aged care and retirement portfolios with portfolio reporting and consolidated compliance records, giving your board and accreditation team one view across every campus. See multi-site maintenance contracts.
Representative Experience

Care and Occupied-Building Work

The kind of aged care and occupied-building work our team is engaged for across South East Queensland. Referee contacts are provided with tender submissions.

Residential aged care and retirement living

Routine AS 1851 servicing planned around care routines, and fire installation at Rosemount Retirement Village.

Staged works on occupied buildings

New works and upgrades staged on live buildings, with isolations managed and reinstated the same shift.

Panel replacement and reprogramming

Fire indicator panels replaced, networked and reprogrammed in house, with staged cut-overs so occupied areas stay protected.

How It Works

A Maintenance Program Built for Care Environments

Facility Audit

We document every fire asset across your site, review existing records and identify any compliance gaps up front.

Care-Aware Plan

Your AS 1851-2012 schedule is mapped around care routines on a twelve month calendar, with alarm testing protocols agreed with your team.

Test & Verify

QBCC licensed technicians complete each frequency on time, verify reinstatement and update your logbook.

Report & Assure

Digital reports after every visit, an annual Certificate of Maintenance and consolidated compliance records for boards and accreditation.

What a Procurement Team Gets

The evidence an evaluator asks for, before they ask

Prequalified and Insured

Cm3 prequalified, FPA Australia member, QBCC 1143420 and electrical contractor licence 1506841. $20M public and products liability, $10M professional indemnity and WorkCover Queensland, certificates of currency on request.

Evidence Every Visit

Digital service report and signed LB6A entry after every visit, photographed defects classified critical or non-critical, annual Certificate of Maintenance and an updated asset register.

Measurable Response

24/7 on call, 2 hour response Gold Coast to Sunshine Coast, critical defects notified within 4 hours, and a standing $500 minor works authority so small defects close on the day.

One Contract, One Calendar

A twelve month service calendar issued before the year starts, CPI-only escalation, and a client portal with unlimited users across every site in the portfolio.

Common Questions

Aged Care Fire Safety FAQs

Why is fire protection different in aged care?
Aged care homes are vulnerable occupancy settings. Many residents have limited mobility or cognitive impairment and cannot self-evacuate quickly, so evacuation relies on staged, staff-assisted movement through fire compartments. That makes every layer of protection critical: working sprinklers, early detection, reliable emergency lighting and intact fire doors all have to perform first time, which is what disciplined AS 1851-2012 and AS/NZS 2293.2 maintenance programs are designed to deliver.
Can you service our facility without disturbing residents?
Yes. We plan servicing around meal times, rest periods and care routines, coordinate alarm testing with your staff so residents are not distressed by unexpected tones, and stage work area by area, with isolations reinstated the same shift.
How often must aged care fire systems be tested?
AS 1851-2012 sets the routine: monthly through five-yearly servicing for sprinklers, fire pumpsets and hydrants, monthly, six-monthly and annual testing for fire detection and alarm systems, six-monthly inspections for extinguishers and hose reels, and six-monthly discharge tests for emergency and exit lighting under AS/NZS 2293.2. Safe QLD manages the entire schedule and keeps your records audit-ready.
Can you provide compliance reporting for our board and accreditation?
Yes. You receive a digital service report and signed LB6A entry after every visit and an annual Certificate of Maintenance, and multi-site providers receive portfolio reporting with consolidated compliance records structured for governance use.