24/7 ON CALL · 2 HR RESPONSE QBCC 1143420 · Cm3 Prequalified · FPA Australia Member Tenders & Prequalification Client Portal Service@SafeQLD.com.auEmail Us (07) 3286 6310
Home / Who We Help / Schools, TAFE & Early Learning

Fire Protection for Schools, TAFE Campuses and Early Learning Groups

Schooling contracts across state and independent schools, TAFE and early learning groups: routine AS 1851 servicing through to new-build detection, EWIS and commissioning, programmed around terms, exams and session times, with consolidated reporting for the business manager or head office.

Cm3 Prequalified QBCC Licence 1143420 Programmed Around Terms 24/7 On Call, 2 Hour Response
Schools, TAFE & Early Learning

Fire Compliance Built Around Terms, Exams and Session Times

A school campus, TAFE or early learning centre is one of the most sensitive occupancies a fire technician can work in. Safe QLD Fire Protection maintains the sprinklers, pumps, hydrants, detection and EWIS that protect students, children and staff, services emergency lighting, passive fire and portables on the same attendance, and programs the work around terms, exams, sessions and sleep times.

Running a group of centres or a campus estate? We deliver group-wide and campus-wide maintenance programs with one point of contact, one twelve month service calendar and consolidated compliance reporting for the business manager or head office. See multi-site maintenance contracts.
AS 1851-2012 AS 1670.1 AS 2419.1 AS 2118 AS/NZS 2293.2 AS 2444 NCC QFD
Fire safety door with DO NOT OBSTRUCT, DO NOT KEEP OPEN signage under an illuminated exit sign

Every System on the Campus, Tested on One Schedule

One provider, one schedule and one digital compliance record across every building on the campus or every centre in the group.

  • Fire detection, alarm and EWIS, monthly, six-monthly and yearly (AS 1851-2012 Section 6, AS 1670.1)
  • Hydrants and boosters across campuses (AS 1851-2012 Section 4, AS 2419.1)
  • Sprinklers in boarding houses and multi-storey teaching blocks (AS 1851-2012 Section 2, AS 2118)
  • Fire pumpsets and water storage where installed (AS 1851-2012 Sections 3 and 5)
  • Emergency and exit lighting discharge testing (AS/NZS 2293.2)
  • Fire doors and passive fire (AS 1851-2012 Section 12)
  • Extinguishers, blankets and hose reels on the same attendance (AS 1851-2012 Sections 9, 10 and 11)
  • Equipment and signage positioned for educator access and child safety in early learning rooms
Working on Live Sites

Term-Time Discipline on Occupied Campuses

Illuminated exit sign mounted above a glazed doorway

Inducted, Signed In and Scheduled Around the Timetable

Schools and early learning centres do not stop for fire testing. Alarm soundings and discharge tests are programmed before opening, after close or in school holidays, and every technician signs in under your visitor and safety procedures.

  • Site induction and site-specific SWMS for every attending technician
  • Alarm testing agreed with the business manager or centre director, never unannounced
  • Emergency lighting discharge tests and EWIS testing programmed out of hours or in school holidays
  • Isolations managed and reinstated the same shift on live teaching sites
Representative Experience

Education Work Across South East Queensland

The kind of education work our team is engaged for. Referee contacts are provided with tender submissions.

State and independent schools

Routine servicing and staged upgrades. Detection installed across 12 buildings at Collingwood Park State High School, and sports hall and multifunction hall fire installation at Springfield Anglican College.

Early learning groups

Group-wide programs with one schedule and consolidated head office reporting.

TAFE campuses

Detection, EWIS and emergency lighting works on live teaching sites.

How It Works

Onboarding a School, Campus or Group

Site Review

We walk each campus or centre, register every fire asset and check the logbook and previous test records.

Twelve Month Calendar

Every AS 1851-2012 frequency on one calendar, issued before the year starts and timed around terms, exams, sessions and sleep times.

Test & Report

QBCC licensed technicians test on schedule and issue a digital service report and signed LB6A entry after every visit.

Defects Closed Out

Critical defects notified within 4 hours and quoted with photographs, with 24/7 on-call support between services.

What a Procurement Team Gets

The evidence an evaluator asks for, before they ask

Prequalified and Insured

Cm3 prequalified, FPA Australia member, QBCC 1143420 and electrical contractor licence 1506841. $20M public and products liability, $10M professional indemnity and WorkCover Queensland, certificates of currency on request.

Evidence Every Visit

Digital service report and signed LB6A entry after every visit, photographed defects classified critical or non-critical, annual Certificate of Maintenance and an updated asset register.

Measurable Response

24/7 on call, 2 hour response Gold Coast to Sunshine Coast, critical defects notified within 4 hours, and a standing $500 minor works authority so small defects close on the day.

One Contract, One Calendar

A twelve month service calendar issued before the year starts, CPI-only escalation, and a client portal with unlimited users across every site in the portfolio.

Common Questions

School, TAFE & Early Learning Fire Safety FAQs

How often does a school or early learning centre's fire equipment need to be tested?
AS 1851-2012 sets the schedule for each system. Fire detection and alarm systems need monthly, six-monthly and annual testing, hydrants, sprinklers and fire pumpsets carry their own routines out to five-yearly, extinguishers and hose reels need six-monthly inspections, and emergency and exit lighting needs six-monthly discharge tests under AS/NZS 2293.2. Safe QLD builds all of these frequencies into one maintenance program so nothing is missed between visits.
Can you service our school or centre without disrupting students and children?
Yes. We schedule testing around lessons, exams, session times, sleep periods and pick-up windows, and we attend before opening, after close or in school holidays where alarm testing would be disruptive. Our technicians are inducted to each site and sign in under your visitor and safety procedures.
Can you run one program across several schools, campuses or centres?
Yes. We register the assets on each site, align the routines to one twelve month calendar and report to the business manager or head office in one consolidated format, with a primary technician assigned to each site.
What compliance records will our school or centre receive?
Every routine inspection and test is recorded as required by AS 1851-2012, including test dates, results, defects found and corrective actions. You receive a digital service report and signed LB6A entry after every visit and an annual Certificate of Maintenance, so the site is always ready for a Queensland Fire Department audit or an assessment and rating visit.
Related

Explore More From Safe QLD

Running fire compliance across more than one site?

One agreement, one service calendar and one consolidated compliance record across the portfolio, with 24/7 cover and a two hour emergency response from the Gold Coast to the Sunshine Coast.

Enquire Here