Extinguishers and Portables, Serviced Under Your AS 1851 Program

Portable equipment is the smallest line on a fire maintenance contract and the one most often serviced badly. Safe QLD supplies and services extinguishers, blankets, hose reels and signage to AS 1851-2012 Sections 9, 10 and 11 and AS 2444 on the same attendance as your sprinklers, hydrants and detection, so a portfolio gets one schedule, one report and one tag standard across every site.

Same attendance as your major systems One tag standard across every site QBCC licensed technicians 24/7 on call
Portable Fire Equipment

One line of a whole-of-building program

A correctly selected, correctly located and correctly maintained extinguisher is often the difference between a small incident and a building fire. Safe QLD services portable equipment as part of a whole-of-building or multi-site program, on the same attendance as the major systems, so the whole building is inspected, tagged and reported in one visit.

Across group-wide equipment programs and multi-site portfolios, our directly employed, QBCC licensed technicians supply, install, test and tag every unit, keep the asset register and digital records audit-ready, and flag defects early so they never become expensive problems. Recent work includes maintenance of a 114-unit portable equipment estate for Silk Contract Logistics at the Port of Brisbane.

AS 1851-2012 Section 10 AS 2444 NCC Building Fire Safety Regulation 2008 QBCC Licence 1143420

Fire Extinguishers

Supply, installation, six-monthly inspections, type-specific five-yearly servicing, recharging and replacement across all extinguisher types.

Fire Blankets

Kitchen and workshop fire blankets supplied and installed to AS 2444, inspected on the same six-monthly cycle as your extinguishers.

Fire Hose Reels

Six-monthly hose reel inspections to AS 1851-2012, checking accessibility, hose condition and operational readiness.

ID & Location Signs

Compliant identification and location signage for every item of equipment, including child-safe height and access requirements for education sites.

Choose The Right Unit

Types of fire extinguishers and what they fight

Using the wrong extinguisher can make a fire worse. Under AS 2444, extinguisher selection must match the fire risks in each area of your building. Here is the quick guide our technicians work from every day.

Extinguisher TypeBand ColourBest ForNever Use On
WaterAll red, no bandClass A fires: wood, paper, textiles and other ordinary combustiblesElectrical equipment, cooking oils, flammable liquids
FoamBlue bandClass A and Class B fires: flammable liquids such as petrol, paint and solventsEnergised electrical equipment
CO2 (Carbon Dioxide)Black bandClass E electrical fires: switchboards, server rooms, plant and office equipmentOutdoor or windy areas where gas disperses; deep fat fryers
ABE Dry ChemicalWhite bandClass A, B and E fires: the most common general purpose unit for offices, warehouses and vehiclesCooking oil fires, sensitive electronics where residue is a concern
Wet ChemicalOatmeal bandClass F fires: cooking oils and fats in commercial kitchensEnergised electrical equipment
Not sure what you need? Safe QLD assesses the fire risks in each area of every site and recommends the right mix, locations and signage to satisfy AS 2444 and the National Construction Code. Coverage reviews against AS 2444 and the NCC are carried out as part of the baseline survey for a maintenance program.
Routine Servicing

Six-monthly inspections to AS 1851-2012

Hose reel and CO2 extinguisher with Safe QLD labels on a warehouse office wall

What our technicians check, every visit

In Queensland, fire safety equipment maintenance is governed by the Building Fire Safety Regulation 2008 and AS 1851. Extinguishers, blankets and hose reels all require six-monthly inspections, and every result is recorded so your building stays audit-ready.

  • Six-monthly extinguisher inspections (AS 1851-2012 Section 10), checking location, access and visibility
  • Anti-tamper seals, safety pins and discharge hoses checked and replaced where needed
  • Pressure gauge readings verified, with CO2 units weighed to confirm contents
  • Cylinder condition inspected for corrosion, dents and damage
  • Fire blankets and hose reels inspected for accessibility, condition and operational readiness
  • Identification signs checked and rectified to AS 2444
  • Service tags stamped and results logged in your digital compliance report
Deeper Maintenance

Pressure testing, recharging and replacement

1 kg ABE dry powder stored pressure extinguisher on a boat

Five-yearly testing that keeps cylinders safe

Beyond the six-monthly cycle, AS 1851-2012 requires a five-yearly service for every extinguisher, with the detail depending on the type: stored pressure units are discharged, internally inspected, refilled and recharged, and cylinders are pressure tested where the type and service history require it. Units are recharged immediately after any use. Pressure testing verifies the integrity of the cylinder itself, so it performs safely when it matters most.

  • Five-yearly hydrostatic pressure testing of extinguisher cylinders where the type requires it (AS 1851-2012), carried out by a specialist cylinder test supplier and managed by Safe QLD
  • Recharge after any discharge, however small, for units on your maintenance program
  • Replacement units supplied where cylinders fail test or reach end of life
  • Only qualified personnel should service extinguishers. All Safe QLD servicing is completed by our own QBCC licensed technicians, with hydrostatic cylinder testing sent to a specialist test supplier.

Every test, recharge and replacement is captured in your maintenance records, because failure to keep compliant records can lead to enforcement action under the Building Fire Safety Regulation 2008.

How It Works

Scheduled and Reported Across Every Site

Site Audit

We assess your building's fire risks and existing equipment against AS 2444 and AS 1851, and price the program clearly, with CPI-only escalation once a year on contract work.

Supply & Install

Compliant equipment supplied and installed with compliant brackets, signage and locations.

Scheduled Servicing

Six-monthly inspections and the five-yearly service, scheduled automatically so nothing is ever missed.

Digital Reporting

Detailed digital compliance reports with defects flagged early, giving you full audit traceability.

Single site or one defect to price? Request a quote.

Common Questions

Fire extinguisher FAQs

How often should fire extinguishers be inspected and tested?
Portable and wheeled fire extinguishers sit under Section 10 of AS 1851-2012, with six-monthly and yearly inspection routines covering pressure, weight, condition, hose and horn, seals, signage, mounting and access, plus a five-yearly service. What that five-yearly involves depends on the extinguisher type, so we confirm it unit by unit rather than applying one rule across the whole site. Extinguishers are also recharged after any use, however brief. Every result is recorded, not just a new tag.
When should fire extinguishers be pressure tested?
At the five-yearly service, and the detail depends on the extinguisher type. Broadly, stored pressure extinguishers are discharged, internally inspected, refilled and recharged, and cylinders are pressure tested where the type and service history require it. Any provider quoting one blanket rule for every unit on your site is guessing. Safe QLD manages the whole cycle, including the cylinders sent away for testing.
What extinguisher types are used, and how is the mix set for a building?
Common types include ABE dry chemical (Class A, B and E fires), CO2 (ideal for electrical fires), foam (effective on flammable liquids), water (Class A combustible materials) and wet chemical (cooking oils and fats). The right mix depends on each building's risks. Safe QLD assesses coverage under AS 2444 as part of the baseline survey for a maintenance program, and holds the same standard across every site in a portfolio.
Is it mandatory to have fire extinguishers in commercial buildings?
For the overwhelming majority of commercial buildings, yes. What must be installed, where and of what type comes from the National Construction Code and AS 2444, assessed against the building's classification and the hazards in it. In Queensland, once installed they become a prescribed fire safety installation under the Building Fire Safety Regulation 2008, and the occupier must keep them maintained by a licensed technician.